(a)The owner or operator shall use the following methods to determine compliance with the applicable emission limits:
(1)Method 1 (40 CFR part 60, appendix A) for the selection of the sampling port location and number of sampling ports;
(2)Method 2 (40 CFR part 60, appendix A) for volumetric flow rate;
(3)Method 3 or 3A (40 CFR part 60, appendix A) for O2 and CO2 for diluent measurements needed to correct the concentration measurements to a standard basis;
(4)Method 4 (40 CFR part 60, appendix A) for moisture content of the stack gas;
(5)Method 5 or Method 29 (40 CFR part 60, appendix A-3) for the concentration of total PM. When using Method 5, each run must consist of a minimum sample volume of 2 dry standard cubic meters (dscm). When using Method 29, each run must consist of a minimum sample volume of 3 dscm. When measuring PM concentration using either Method 5 or 29, the probe and filter holder heating system must be set to provide a gas temperature no greater than 120±14 °C (248±25 °F).
(6)For measuring the concentration of formaldehyde, use one of the following test methods:
(i)Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra.
(ii)Method 316 (appendix A of this part). Each test run must consist of a minimum of 2 dry standard cubic meters
(dscm)of sample volume.
(7)Method contained in appendix A of this subpart for the determination of product LOI;
(8)Method contained in appendix B of this subpart for the determination of the free-formaldehyde content of resin. The owner or operator shall use vendor specifications to determine the free-phenol content of resin.
(9)Method contained in appendix C of this subpart for the determination of product density;
(10)For measuring the concentration of phenol, use Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra.
(11)For measuring the concentration of methanol, use one of the following test methods:
(i)Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra.
(ii)Method 308 (appendix A of this part). Each test run must consist of a minimum of 2 hours.
(12)Method 29 (40 CFR part 60, appendix A-8) for the concentration of chromium compounds. Each test run must consist of a minimum sample volume of 3 dscm.
(13)An alternative method, subject to approval by the Administrator.
(b)Each performance test shall consist of 3 runs. The owner or operator shall use the average of the three runs in the applicable equation for determining compliance. [64 FR 31709, June 14, 1999, as amended at 80 FR 45335, July 29, 2015; 82 FR 60885, Dec. 26, 2017]
Connections1 cite this
Cited by 1 section
1 reference not yet in our index
  • 40 CFR 60
Citation graph
cites case law
§ 63.1385
Test methods and procedures.
Fed. Reg.×1
Cite40 CFR 60
Cites 1Cited by 1 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.